BASIC INFORMATION

INPUTS / OUTPUTS

Analogue current inputs 0-27mA (4-20 mA)

4 x

Binary inputs with GS

2 x

Binary outputs, low side switch

2 x

Analogue voltage outputs 0-10 V /20 mA

2 x

COMMUNICATION

CAN Physical layer

1 x ISO 11898-2

CAN Protocol

CANopen

PARAMETERS

Rated power supply voltage

24 V DC (16 ÷ 31,2 V DC)

Power supply interrupt category

S1

Max quiescent current consumption from UB+ terminal (no output active, no communication)

20 mA

Operating temperature

-30 to +70 °C

Internal protection

IP20

Pollution degree

PD2

Dimensions without connector mates

80 x 93 x 37 mm

Weight

320 g

 

APPLIED MODIFICATIONS

DESIGN: CATALOG NUMBER:

PPS-1/01 J1939

08-15-20-00-01

PPS-1/02 CANopen 08-15-20-00-02

 

REFERENCES

  • Motor temperature monitoring in PESA SWING tram for Szeged (delivered to Cegelec a.s)
  • Traction converters temperature control in trolleybuses for Salzburg (delivered to Cegelec a.s)